Guard Column Cartridges, RP C18 Wide Pore, 10um, 300A. 4.0mm ID x 10mm Length. Cogent Brand. 5/PK.
Additional Info:
The 68018‑PG2‑3 Cogent RP C18 Wide Pore Guard Column Cartridges are designed to extend the life of analytical HPLC columns, providing protection from particulates, strongly retained compounds, and sample matrix contamination in routine and advanced workflows.
Packed with 10 µm Cogent RP C18™ Wide Pore stationary phase (300 Å) and manufactured using high‑purity silica with traditional octadecylsilane (C18) bonding, these cartridges are fully double end‑capped to provide:
Reduced silanol activity
Improved peak shape for proteins, peptides, and large polar analytes
Consistent and reproducible chromatographic protection
Each cartridge is constructed in a stainless steel body with stainless steel frits, secured with PEEK frit caps for durability and proper sealing in analytical systems.
Designed for Analytical Columns (3.0–4.6 mm ID)
Compatible with:
3.0 mm ID solvent‑saving columns
4.0 mm ID analytical columns
4.6 mm ID standard HPLC columns
✅ Maintains method integrity and chromatographic consistency
300 Å Wide Pore – Biomolecule Protection
Designed specifically for:
Proteins
Peptides
Large molecular weight compounds
Prevents:
Restricted diffusion
Pore blocking seen with 100 Å media
✅ Essential for biomolecule methods and LC‑MS workflows
Purpose of Guard Columns
Protect analytical columns from:
Particulate contamination
Strongly retained biomolecules
Matrix buildup and fouling
Extend column lifetime
Maintain retention consistency and peak shape
Reduce downtime and replacement costs
10 µm Guard Media – Durability & Compatibility
Provides robust performance in high‑load analytical workflows
Ideal for method development and QC environments
Offers extended guard life compared to smaller particle guards
✅ Supports longer service intervals in demanding workflows
Why Choose Wide Pore Guard Cartridges (10 µm, 300 Å)
Matched Biomolecule Chemistry
Same wide‑pore C18 chemistry as primary column
Maintains selectivity and chromatographic behavior
Prevents unexpected method changes
Enhanced Biomolecule Protection
Captures large analytes and strongly retained compounds before reaching column
Reduces column fouling and degradation
Workflow Efficiency
Minimizes column downtime and maintenance
Essential for high‑throughput and LC‑MS laboratories
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Enhances reproducibility
High Purity Silica
Reliable performance across runs
Consistent guard‑to‑guard quality
Durable Construction
Stainless steel cartridge body and frits
PEEK‑based sealing system
Designed for routine analytical use
Important Usage Notes
⚠️ Must be used with a compatible guard column holder system
Replace regularly to maintain optimal column performance
Critical for protecting high‑value analytical columns