HPLC Column, RP PFP, 10um, 4.6mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.

Additional Info:

68022-05P Cogent RP PFP™ HPLC Column has been a premium value trusted by HPLC laboratories for many years, delivering reliable performance and enhanced selectivity for targeted separations. This column is fully double end‑capped and bonded via a four‑carbon linker to a benzene ring substituted with five fluorine atoms, using ultra‑high purity silica.

The column enables multiple retention mechanisms—including π‑π interactions, dipole interactions, and hydrogen bonding—making it especially effective for halogenated, aromatic, and polar analytes. It is also suitable as an alternate column for USP methods requiring L43 classification.

With a 10 µm particle size, this column provides very low backpressure compared to smaller particle sizes, allowing higher flow rates and improved system compatibility, particularly in methods where pressure limitations are a concern.

50 mm Length – Fast Screening and High Throughput

The 50 mm length is optimized for rapid separations and high‑throughput workflows.

  • Very fast run times for screening applications

  • Reduced solvent consumption

  • Ideal for early-stage method development

✅ Recommended for fast analytical workflows and high‑flow operation

Flow Rate & System Requirements (4.6 mm ID, 10 µm)

⚠️ Fully compatible with standard analytical HPLC systems and ideal for low-pressure operation

  • Typical flow rate range: ~1.0 – 2.5 mL/min

  • Very low backpressure vs 5 µm and 3 µm columns

  • Supports higher flow rates for faster analyses

  • Suitable for UV and standard detectors

✅ Best Practice: Filter samples using a 0.2 µm syringe filter prior to injection

Why Choose PFP (F5) Columns for Selective Separations

Enhanced Retention for Halogenated Compounds

  • Strong interaction with fluorinated and halogenated analytes

  • Improved selectivity vs C18 columns

Multiple Interaction Mechanisms

  • π‑π interactions for aromatic compounds

  • Dipole interactions and hydrogen bonding

  • Increased flexibility for method optimization

100 Å Pore Structure

  • Suitable for small to moderately sized molecules

  • Broad applicability across analytical methods

Cogent RP PFP™ Column Advantages

Fully End‑Capped Surface

  • Minimizes silanol activity

  • Improves peak symmetry

Low Backpressure (10 µm Particles)

  • Ideal for high flow rate methods

  • Reduced strain on HPLC systems

High Purity Silica

  • Consistent chromatographic performance

  • Reliable reproducibility

Typical Applications

  • Fast screening and high‑throughput analysis

  • Halogenated compound separations

  • Aromatic compound analysis

  • Method development and optimization

  • USP L43 methods

Important Usage Notes

  • Packed and shipped in reversed‑phase solvents

  • Designed for standard analytical HPLC systems (4.6 mm ID)

  • Very low backpressure compared to smaller particle columns

  • Use 0.2 µm filtration prior to injection

 