HPLC Column, RP Cyano, Wide Pore, 10um, 4.0mm ID x 250mm Length, 300A. Cogent Brand. 1 EA.

Additional Information:

Cogent RP Cyano Wide Pore is a versatile reversed-phase stationary phase designed for HPLC methods requiring lower hydrophobic retention, rapid equilibration, and alternative selectivity compared to traditional C18 columns. Manufactured using high-purity silica with a cyanopropyl (CN) bonded phase, it provides balanced retention for polar and moderately hydrophobic compounds while serving as an effective USP L10 alternative. The 300 Å wide pore structure improves analyte accessibility for larger molecules, making it particularly useful for proteins, peptides, enzymes, and other high molecular weight compounds.

68034-25P-4-3M is an analytical HPLC column packed with 10 µm RP Cyano Wide Pore particles featuring a 300 Å pore size in a 4.0 mm ID x 250 mm format. The 250 mm column length maximizes resolving power and peak capacity for complex separations where the highest chromatographic resolution is required. The 10 µm particle size supports lower operating backpressure and allows higher flow rates when appropriate. Typical operating flow rates are approximately 0.8–1.5 mL/min depending on mobile phase composition, analyte characteristics, and instrument configuration.

This column is commonly used for proteins, peptides, enzymes, natural products, and other larger polar or neutral compounds. It is frequently selected for USP L10 methods, biomolecule analysis, pharmaceutical development, impurity profiling, and preparative method scouting involving larger molecules where maximum chromatographic performance is desired.

Key Benefits

  • RP Cyano Wide Pore stationary phase

  • USP L10 column equivalent chemistry

  • Cyanopropyl bonded phase

  • 300 Å pore size for larger molecules

  • High-purity silica support

  • Alternative selectivity to C18 columns

  • Faster equilibration than many traditional reversed-phase columns

  • Reduced hydrophobic retention

  • Suitable for polar and neutral compounds

  • Maximum resolving power for biomolecule separations

Typical Applications

  • USP L10 methods

  • Peptide analysis

  • Protein separations

  • Enzyme analysis

  • Natural product analysis

  • Pharmaceutical analysis

  • Biomolecule characterization

  • Impurity profiling

  • Method development

  • Preparative method scouting

Specifications

  • Product Type: HPLC Column

  • Stationary Phase: RP Cyano Wide Pore

  • USP Classification: L10

  • Chromatography Mode: Reversed Phase

  • Bonded Phase: Cyanopropyl (CN)

  • Endcapping: Not Endcapped

  • Particle Size: 10 µm

  • Pore Size: 300 Å

  • Column Dimensions: 4.0 mm ID x 250 mm

  • Length: 250 mm

  • Typical Flow Rate: 0.8–1.5 mL/min

  • Brand: Cogent

Additional Resources

Special Order Item Information

Important Notes

  • Packed and shipped in reversed-phase solvents

  • Wide pore design improves accessibility for proteins, peptides, enzymes, and other larger molecules

  • Extended column length maximizes resolution and peak capacity

  • Frequently selected for USP L10 methods involving larger analytes

  • Useful for preparative method scouting and method transfer studies

  • This is a custom manufactured item and cannot be canceled or returned once ordered


 