UHPLC Column, RP Cyano, 1.8um, 100A. 2.1mm ID x 150mm Length. Cogent Brand. 1 EA.
Additional Information:
Cogent RP Cyano™ is a versatile reversed-phase UHPLC stationary phase designed for polar and neutral compound separations where reduced retention and rapid equilibration are desired. Manufactured with a cyanopropyl bonded phase on ultra-high purity silica and supplied without endcapping, this chemistry provides distinct selectivity compared to traditional alkyl phases. RP Cyano™ is commonly used as an alternative for USP L10 methods and offers shorter retention times than many conventional reversed-phase columns while maintaining excellent chromatographic performance.
68134-15P-2 is a UHPLC column packed with 1.8 µm RP Cyano™ particles featuring a 100 Å pore size in a 2.1 mm ID x 150 mm format. The 150 mm length maximizes resolution and peak capacity for complex sample separations, while the sub-2 µm particle technology delivers exceptional efficiency. This column is specifically engineered for high-pressure UHPLC operation and is designed to take full advantage of UHPLC instrumentation capable of operating at the elevated pressures generated by 1.8 µm particles. Typical operating flow rates are approximately 0.2–0.4 mL/min. Because of the low flow rates required by 2.1 mm ID columns, standard HPLC systems must be capable of precise and reproducible low-flow operation if they are used with this column.
This column is particularly useful for polar and neutral compounds requiring reversed-phase retention with shorter retention times than many traditional alkyl phases. The combination of RP Cyano™ selectivity and UHPLC efficiency makes it an excellent choice for LC-MS methods, impurity profiling, method development, and complex sample analyses requiring maximum resolving power.
Key Benefits
RP Cyano™ stationary phase
USP L10 equivalent chemistry
Cyanopropyl bonded phase
Ultra-high purity silica support
Designed for UHPLC applications
High-efficiency 1.8 µm particles
Unique selectivity compared to C8 and C18 phases
Shorter retention times for many analytes
Rapid equilibration between runs
Ideal for LC-MS methods
Typical Applications
USP L10 methods
UHPLC analysis
LC-MS methods
Polar compound analysis
Neutral compound analysis
Pharmaceutical analysis
Method development
Impurity profiling
Complex sample separations
Quality control testing
Specifications
Product Type: UHPLC Column
Stationary Phase: RP Cyano™
USP Classification: L10
Chromatography Mode: Reversed Phase
Bonded Phase: Cyanopropyl
Endcapping: Not Endcapped
Particle Size: 1.8 µm
Pore Size: 100 Å
Column Dimensions: 2.1 mm ID x 150 mm
Length: 150 mm
Typical Flow Rate: 0.2–0.4 mL/min
Brand: Cogent
Important Notes
Designed specifically for UHPLC operation and high-pressure reversed-phase chromatography
1.8 µm particles generate substantially higher backpressure than conventional HPLC columns
Maximum performance is achieved on UHPLC systems designed for sub-2 µm particle technology
The 2.1 mm ID format is commonly used for LC-MS applications
Standard HPLC systems must be capable of precise and reproducible operation at approximately 0.2–0.4 mL/min
Packed and shipped in reversed-phase solvents
View Cogent NP Cyano Columns packed in Normal Phase solvents for Normal Phase applications
The 150 mm length maximizes resolution and peak capacity for complex sample separations
Samples should be filtered through a 0.2 µm syringe filter prior to injection