HPLC Column, RP Cyano, Wide Pore, 3um, 2.1mm ID x 100mm Length, 300A. Cogent Brand. 1 EA.

Additional Information:

Cogent RP Cyano™ Wide Pore is a versatile reversed-phase HPLC stationary phase designed for the separation of larger polar and neutral compounds. Manufactured using a three-carbon ligand with a terminal cyano (CN) functional group bonded to ultra-high purity silica, this 300 Å wide pore stationary phase provides selectivity distinct from traditional C18, C8, and phenyl phases while offering increased accessibility for large analytes. As a USP L10 equivalent phase, it is particularly useful for proteins, peptides, enzymes, natural products, and other larger molecules that benefit from wide pore chromatography.

68334-10P-2-3M is an HPLC column packed with 3 µm RP Cyano™ Wide Pore particles featuring a 300 Å pore size in a 2.1 mm ID x 100 mm format. This narrow-bore configuration combines enhanced chromatographic resolution with reduced solvent consumption and excellent compatibility with LC-MS instrumentation. The 100 mm length provides greater resolving power than shorter 50 mm columns, while the wide pore structure improves analyte access to the bonded phase for larger compounds. Typical operating flow rates are approximately 0.2–0.3 mL/min. Because of the low flow rates required by 2.1 mm ID columns, standard HPLC systems must be capable of precise and reproducible low-flow operation.

This column is particularly useful for large polar or neutral compounds including proteins, peptides, enzymes, and natural products analyzed by reversed-phase HPLC and LC-MS methods. Compared to non-modified silica columns, the RP Cyano™ Wide Pore phase typically provides shorter retention times and faster equilibration between runs, making it an excellent choice for bioanalytical, pharmaceutical, and research applications requiring enhanced resolution and alternative selectivity.

Key Benefits

  • RP Cyano™ Wide Pore stationary phase

  • USP L10 equivalent chemistry

  • Cyano bonded phase

  • Ultra-high purity silica support

  • 300 Å wide pore design

  • Optimized for large molecules

  • Alternative selectivity to C18 and C8 phases

  • Faster equilibration between runs

  • 3 µm particle size

  • Excellent for LC-MS applications

Typical Applications

  • USP L10 methods

  • LC-MS methods

  • Protein analysis

  • Peptide analysis

  • Enzyme analysis

  • Natural product analysis

  • Polar compound analysis

  • Neutral compound analysis

  • Bioanalytical methods

  • Reversed-phase HPLC

Specifications

  • Product Type: HPLC Column

  • Stationary Phase: RP Cyano™ Wide Pore

  • USP Classification: L10

  • Chromatography Mode: Reversed Phase

  • Bonded Phase: Cyano (CN)

  • Endcapping: Not End Capped

  • Particle Size: 3 µm

  • Pore Size: 300 Å

  • Column Dimensions: 2.1 mm ID x 100 mm

  • Length: 100 mm

  • Typical Flow Rate: 0.2–0.3 mL/min

  • Brand: Cogent

Important Notes

  • Designed for larger molecules including proteins, peptides, enzymes, and natural products

  • 300 Å wide pores improve access to the bonded phase for large analytes

  • Provides alternative selectivity compared to C18, C8, and Phenyl phases

  • Suitable for reversed-phase HPLC and LC-MS applications

  • The 2.1 mm ID format is commonly used for LC-MS applications

  • Standard HPLC systems must be capable of precise and reproducible operation at approximately 0.2–0.3 mL/min

  • Detector flow cells should be optimized for low-volume, narrow-bore chromatography

  • 3 µm particles provide higher efficiency and sharper peaks than comparable 5 µm columns

  • The 100 mm length provides greater resolution than 50 mm columns while maintaining practical run times

  • Packed and shipped in reversed-phase solvents

  • For normal-phase applications, see the related Cogent NP Cyano Columns packed in normal-phase solvents


 