HPLC Column, RP C18, 5um, 4.6mm ID x 150mm Length, 100A. Cogent Brand. 1 EA.
Additional Info:
The 68518‑15P Cogent RP C18 HPLC Column is designed for high‑resolution analytical separations, featuring 5 µm particles and fully double end‑capped C18 bonding to provide reliable retention, improved peak shape, and consistent performance.
Manufactured using high‑purity silica with traditional octadecylsilane (C18) chemistry, this stationary phase offers:
Complete end‑capping to minimize silanol interactions
Improved peak symmetry for polar and basic analytes
Consistent, reproducible chromatography across methods
This column is widely used as a primary analytical column, a starting point for new method development, and as a USP L1 alternate for 5 µm applications.
150 mm Length – Maximum Resolution & Peak Capacity
Highest resolving power in the 4.6 mm RP C18 range
Maximizes peak capacity for complex mixtures
Ideal for closely related compounds and difficult separations
Preferred for final method optimization and high‑purity analysis
Longer run times compared to 50 mm and 100 mm formats
This format is commonly chosen when maximum separation is required and shorter columns do not provide sufficient resolution.
4.6 mm ID – Standard Analytical Performance
Industry‑standard HPLC column dimension
Compatible with all conventional HPLC systems
Typical flow rate range: ~0.8–1.5 mL/min
Optimal starting range: ~1.0–1.2 mL/min
Provides:
Strong detector response
Excellent reproducibility
Straightforward method transfer between systems
Flow Rate & System Considerations (4.6 mm ID, 5 µm)
Suitable for conventional HPLC systems
Supports higher flow rates compared to smaller particle sizes
Well suited for:
Viscous mobile phases
Extended gradients
Routine and long analytical runs
Why Choose RP C18 (5 µm)
Robust & Reliable Operation
Ideal for routine analytical workflows
Lower backpressure relative to smaller particle sizes
Suitable for long‑lifetime methods and consistent results
Reliable Hydrophobic Retention
Strong reversed‑phase retention for hydrophobic and neutral compounds
Excellent for long‑chain fatty acids
Provides greater retention than C8 phases
Method Development & USP Compatibility
Ideal for method development and optimization
Suitable for USP L1 methods using 5 µm particles
Commonly used as a starting platform for new methods
Cogent RP C18™ Advantages
Fully End‑Capped Surface
Minimizes secondary interactions
Improves peak symmetry
Better performance for basic analytes
High Purity Silica
Consistent chromatographic performance
Reduced variability between runs
Durable & Cost‑Efficient
Long column lifetime
Reduced system wear
Lower maintenance frequency
Typical Applications
Pharmaceutical and QC analysis
Hydrophobic and neutral compound separations
Long‑chain fatty acids
Complex analytical methods
Method development and validation
USP L1 reversed‑phase workflows
Important Usage Notes
Compatible with standard HPLC systems
Ideal for maximum‑resolution analytical workflows
Best suited when complex separations require high peak capacity
Optimize method conditions to balance resolution and run time