HPLC Column, C30, 10um, 4.6mm ID x 50mm Length, 200A. Cogent Brand. 1 EA.
Additional Info:
The 72030‑05P Cogent C30™ HPLC Column is designed for shape‑selective separation of long‑chain hydrophobic compounds, providing unique resolution of positional and geometric isomers that are difficult to separate with conventional C18 phases.
This column features a 30‑carbon bonded stationary phase on high‑purity silica (non‑end capped), delivering stronger hydrophobic interaction and a distinct selectivity profile under reversed‑phase conditions.
With a 200 Å pore size, it is well suited for larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining consistent chromatographic performance.
✅ Comparable selectivity and application performance to YMC® C30 columns, making it a reliable alternative for USP L62 methods and equivalent workflows
50 mm Length – Fast Screening & Preparative Scouting
The 50 mm length is optimized for rapid separations and method scouting, particularly useful when developing conditions prior to scale‑up.
Short run times and fast method evaluation
Efficient for selectivity testing and screening
Reduced solvent usage
✅ Use when developing methods intended for semi‑prep or preparative scale
Flow Rate & System Requirements (4.6 mm ID, 10 µm)
⚠️ Compatible with standard HPLC systems, with lower backpressure compared to smaller particles
Typical flow rate range: ~0.8–2.0 mL/min
Can support higher flow rates due to larger particle size
Lower system pressure vs 3 µm and 5 µm columns
Standard analytical detector compatibility
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection
Why Choose C30 for Hydrophobic Separations
Shape Selectivity for Isomers
Resolves positional and geometric isomers
Provides separation beyond traditional C18 capability
Effective for Larger Molecules
200 Å pore supports complex analytes
Ideal for carotenoids, vitamins, and peptides
Reversed‑Phase Alternative to Normal Phase
Avoids instability and reproducibility issues
Maintains consistent chromatographic performance
Cogent C30™ Advantages
Extended C30 Ligand
Stronger hydrophobic interaction vs C18
Unique selectivity for long‑chain compounds
High Purity Silica
Consistent column performance
Reliable reproducibility across methods
Method Transfer Capability
Comparable to YMC® C30 column chemistry and applications
Suitable for transferring L62 methods with minimal adjustment
Typical Applications
Carotenoid and vitamin analysis
Isomer and positional compound separations
Peptide and large molecule separations
Hydrophobic compound profiling
Method development and preparative scouting
Important Usage Notes
Designed for standard HPLC systems (4.6 mm ID)
Not end‑capped (intentional for selectivity differences)
Lower backpressure vs smaller particle sizes
Ideal for method development and scale‑up workflows