HPLC Column, C30, 10um, 4.6mm ID x 250mm Length, 200A. Cogent Brand. 1 EA.
Additional Info:
The 72030‑25P Cogent C30™ HPLC Column is designed for maximum‑resolution, shape‑selective separation of long‑chain hydrophobic compounds, delivering reliable performance for positional and geometric isomers that are difficult to resolve with conventional C18 phases.
This column utilizes a 30‑carbon bonded stationary phase on high‑purity silica (non‑end capped), providing enhanced hydrophobic interaction and a unique selectivity profile that enables accurate separation of structurally similar compounds under reversed‑phase conditions.
The 200 Å pore size supports larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining consistent retention and chromatographic behavior.
✅ Comparable selectivity and application performance to YMC® C30 columns, making it a dependable alternative for USP L62 methods and equivalent workflows
250 mm Length – Maximum Resolution Before Scale‑Up
The 250 mm length provides the highest resolving power in the 10 µm C30 analytical range, making it ideal for difficult separations and final method optimization prior to preparative scaling.
Maximum separation of positional and geometric isomers
Highest peak capacity for complex mixtures
Improved purity and resolution of closely eluting compounds
✅ Use when 150 mm columns do not achieve required resolution or separation quality
Flow Rate & System Requirements (4.6 mm ID, 10 µm)
⚠️ Compatible with standard HPLC systems, with significantly lower backpressure than smaller particle sizes
Typical flow rate range: ~0.8–2.0 mL/min
Supports higher flow rates due to 10 µm particles
Lower pressure vs 3 µm and 5 µm columns
Monitor pressure when using longer column length and viscous solvents
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection
Why Choose C30 for Hydrophobic Separations
Maximum Shape Selectivity
Resolves positional and geometric isomers
Enables separations beyond traditional C18 columns
Effective for Larger Molecules
200 Å pore enhances interaction with complex analytes
Ideal for carotenoids, vitamins, and peptides
Robust Alternative to Normal Phase
Avoids instability and variability issues
Maintains consistent reversed‑phase performance
Cogent C30™ Advantages
Extended C30 Ligand
Stronger hydrophobic interaction vs C18
Unique selectivity for long‑chain compounds
High Purity Silica
Consistent chromatographic performance
Reliable reproducibility across runs
Method Transfer Capability
Comparable to YMC® C30 column chemistry and applications
Suitable for transferring L62 methods with minimal adjustment
Typical Applications
Carotenoid and vitamin analysis
Isomer and positional compound separations
Peptide and large molecule separations
Hydrophobic compound profiling
Method development and pre‑preparative optimization
Important Usage Notes
Designed for standard analytical HPLC systems (4.6 mm ID)
Not end‑capped (intentional for selectivity differences)
Lower backpressure vs smaller particle sizes
Ideal for maximum‑resolution method development and scale‑up workflows