HPLC Column, C30, 3um, 4.6mm ID x 50mm Length, 200A. Cogent Brand. 1 EA.

Additional Info:

The 72330‑05P Cogent C30™ HPLC Column is designed for enhanced shape selectivity and separation of long‑chain hydrophobic compounds, delivering superior resolution for positional and geometric isomers compared to standard C18 phases.

Manufactured using a 30‑carbon bonded phase on high‑purity silica (non‑end capped), this stationary phase provides stronger hydrophobic interaction and a different selectivity profile than traditional reversed‑phase columns. This makes it especially useful when conventional C18 methods cannot resolve structurally similar compounds.

The 200 Å pore size further expands its applicability to larger molecules, including carotenoids, vitamins, peptides, and some proteins.

50 mm Length – Fast Screening & Method Development

At 50 mm, this column is optimized for fast separations and efficient method scouting, ideal for evaluating selectivity before moving to longer columns.

  • Short run times and rapid gradients

  • Efficient screening for complex mixtures

  • Reduced solvent usage

✅ Use when fast method development and selectivity evaluation are priorities

Flow Rate & System Requirements (4.6 mm ID, 3 µm)

⚠️ Compatible with standard HPLC systems, but higher pressure than 5 µm columns should be expected

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Optimal starting range: ~1.0–1.2 mL/min

  • Standard analytical detector compatible

  • Monitor system pressure due to 3 µm particle size

✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection

Why Choose C30 for Hydrophobic Separations

Shape Selectivity for Isomers

  • Resolves positional and geometric isomers

  • Superior to C18 for structurally similar compounds

Ideal for Large Hydrophobic Molecules

  • 200 Å pore supports larger analytes

  • Effective for carotenoids, vitamins, and peptides

Alternative to Normal Phase Methods

  • Avoids instability and variability of normal phase

  • Works under reversed‑phase conditions

Cogent C30™ Advantages

Extended C30 Ligand

  • Stronger hydrophobic interaction vs C18

  • Unique selectivity profile

High Purity Silica

  • Consistent performance and reproducibility

  • Reliable chromatographic behavior

Efficient Analytical Format (4.6 mm)

  • Compatible with standard HPLC systems

  • Ideal for method development and QC workflows

Typical Applications

  • Carotenoid and vitamin analysis

  • Isomer and positional compound separation

  • Peptide and large molecule analysis

  • Hydrophobic compound profiling

  • Method development and optimization

Important Usage Notes

  • Designed for standard analytical HPLC systems (4.6 mm ID)

  • Not end‑capped (intentional for selectivity)

  • Higher backpressure vs 5 µm columns

  • Ideal for shape‑selective separations where C18 is insufficient

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media