HPLC Column, C30, 3um, 2.1mm ID x 50mm Length, 200A. Cogent Brand. 1 EA.
Additional Info:
The 72330‑05P‑2 Cogent C30™ HPLC Column is designed for enhanced shape selectivity and separation of long‑chain hydrophobic compounds, delivering improved resolution for positional isomers and structurally similar analytes.
Manufactured using a 30‑carbon bonded phase on high‑purity silica (non‑end capped), this column provides different selectivity compared to traditional C18 phases. The extended ligand length increases hydrophobic interaction and enables separation mechanisms not achievable with standard reversed‑phase columns.
The 200 Å pore size makes this column well suited for larger molecules, including carotenoids, vitamins, peptides, and some proteins.
50 mm Length – Fast Screening & Method Development
The 50 mm length is optimized for rapid separations, making it ideal for screening and early method development work.
Short run times and fast gradients
Efficient for method scouting
Reduced solvent consumption
✅ Use when speed and method development flexibility are priorities
Flow Rate & System Requirements (2.1 mm ID, 3 µm)
⚠️ Requires low‑flow HPLC or LC‑MS system capability
Typical flow rate range: ~0.2–0.3 mL/min
Requires precise low‑flow pump control
Compatible with low‑volume LC‑MS detector systems
Higher backpressure vs 5 µm columns
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection
Why Choose C30 for Hydrophobic Separations
Enhanced Shape Selectivity
Separates positional and geometric isomers
Provides resolution not achievable with C18
Ideal for Large Hydrophobic Molecules
Effective for carotenoids, vitamins, and peptides
200 Å pore supports larger analyte access
Alternative to Normal Phase
Avoids common issues with normal phase chromatography
Works under reversed‑phase conditions
Cogent C30™ Advantages
Extended Carbon Chain (C30)
Stronger hydrophobic interaction than C18
Improved selectivity for long‑chain compounds
High Purity Silica
Consistent performance and reproducibility
Reliable peak shape across runs
LC‑MS Compatibility
Narrow 2.1 mm format optimized for sensitivity
Ideal for low‑flow analytical systems
Typical Applications
Carotenoid and vitamin analysis
Peptide and large molecule separations
Isomer and positional variant separation
Hydrophobic compound profiling
LC‑MS analytical workflows
Important Usage Notes
Designed for low‑flow LC‑MS systems (~0.2–0.3 mL/min)
Not end‑capped (intentional for selectivity differences)
Higher backpressure vs 5 µm columns
Ideal for shape‑selective separations and method development