HPLC Column, C30, 3um, 4.6mm ID x 100mm Length, 200A. Cogent Brand. 1 EA.

Additional Info:

The 72330‑10P Cogent C30™ HPLC Column is designed for enhanced shape selectivity and improved separation of long‑chain hydrophobic compounds, delivering superior resolution of positional and geometric isomers compared to standard C18 phases.

Manufactured with a 30‑carbon bonded phase on high‑purity silica (non‑end capped), this column provides stronger hydrophobic interaction and a distinct selectivity profile that enables separations not achievable with traditional reversed‑phase columns.

With a 200 Å pore size, it is especially effective for larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining excellent chromatographic performance.

100 mm Length – Increased Resolution for Analytical Methods

The 100 mm length offers a balance between speed and resolution, allowing improved separation without the longer run times of 150 mm or 250 mm columns.

  • Better resolution than 50 mm screening columns

  • Improved separation of closely related isomers

  • Increased peak capacity for complex samples

✅ Use when additional resolving power is required beyond fast screening methods

Flow Rate & System Requirements (4.6 mm ID, 3 µm)

⚠️ Compatible with standard HPLC systems, but higher pressure than 5 µm columns should be expected

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Optimal starting range: ~1.0–1.2 mL/min

  • Standard analytical detector compatible

  • Monitor system pressure due to smaller particle size

✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection

Why Choose C30 for Hydrophobic Separations

Shape Selectivity for Isomers

  • Resolves positional and geometric isomers

  • Provides separation beyond traditional C18 capability

Optimized for Larger Molecules

  • 200 Å pore improves accessibility for complex analytes

  • Ideal for carotenoids, vitamins, and peptides

Reliable Alternative to Normal Phase

  • Eliminates instability and variability of normal phase methods

  • Maintains reproducible reversed‑phase operation

Cogent C30™ Advantages

Extended C30 Ligand

  • Stronger hydrophobic interaction than C18

  • Unique selectivity for long‑chain compounds

High Purity Silica

  • Consistent column‑to‑column performance

  • Reliable and reproducible results

Analytical 4.6 mm Format

  • Compatible with standard HPLC systems

  • Ideal for method development and routine workflows

Typical Applications

  • Carotenoid and vitamin analysis

  • Isomer and positional compound separation

  • Peptide and larger molecule separations

  • Hydrophobic compound profiling

  • Method development and optimization

Important Usage Notes

  • Designed for standard analytical HPLC systems (4.6 mm ID)

  • Not end‑capped (intentional for enhanced selectivity)

  • Higher backpressure vs 5 µm columns

  • Ideal for shape‑selective separations where C18 is insufficient

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media