HPLC Column, C30, 3um, 4.6mm ID x 250mm Length, 200A. Cogent Brand. 1 EA.

Additional Info:

The 72330‑25P Cogent C30™ HPLC Column is engineered for maximum‑resolution, shape‑selective separations of long‑chain hydrophobic compounds, providing exceptional performance for positional and geometric isomers that cannot be fully resolved with traditional C18 phases.

This column features a 30‑carbon bonded stationary phase on high‑purity silica (non‑end capped), delivering enhanced hydrophobic interaction and a distinct selectivity profile that enables accurate differentiation of closely related compounds.

The 200 Å pore size makes it particularly effective for larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining excellent peak shape and reproducibility.

✅ Comparable selectivity and application performance to YMC® C30 columns, making it an ideal alternative for USP L62 methods and equivalent workflows

✅ One of the most popular C30 columns for high‑resolution analytical separations

250 mm Length – Maximum Resolution & Separation Power

The 250 mm length provides the highest resolving power in the C30 analytical range, allowing separation of complex mixtures and closely related isomers with maximum clarity.

  • Highest peak capacity for complex samples

  • Superior separation of positional and geometric isomers

  • Improved detection of trace impurities

✅ Use when 150 mm columns cannot achieve required separation or purity

Flow Rate & System Requirements (4.6 mm ID, 3 µm)

⚠️ Compatible with standard HPLC systems, but system pressure must be monitored carefully due to column length and particle size

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Recommended starting range: ~1.0–1.2 mL/min

  • Longer column length increases backpressure

  • Extra caution with viscous mobile phases

✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection

Why Choose C30 for Hydrophobic Separations

Maximum Shape Selectivity

  • Resolves positional and geometric isomers

  • Enables separations beyond standard C18 capability

Optimized for Larger Molecules

  • 200 Å pore improves access for complex compounds

  • Ideal for carotenoids, vitamins, and peptides

Reliable Alternative to Normal Phase

  • Avoids instability and variability of normal phase

  • Maintains reproducible reversed‑phase operation

Cogent C30™ Advantages

Extended C30 Ligand

  • Stronger hydrophobic interaction than C18

  • Unique selectivity for long‑chain analytes

High Purity Silica

  • Consistent chromatographic performance

  • Reliable results across runs and methods

Method Transfer Capability

  • Comparable to YMC® C30 column chemistry and applications

  • Suitable for transferring L62 methods with minimal modification

Typical Applications

  • Carotenoid and vitamin analysis

  • Isomer and positional compound separations

  • Peptide and large molecule separations

  • Hydrophobic compound profiling

  • High‑resolution method development

Important Usage Notes

  • Designed for standard analytical HPLC systems (4.6 mm ID)

  • Not end‑capped (intentional for enhanced selectivity)

  • Higher backpressure due to 3 µm particle and 250 mm length

  • Ideal for maximum‑resolution, shape‑selective separations

 