HPLC Column, C30, 5um, 4.6mm ID x 150mm Length, 200A. Cogent Brand. 1 EA.

Additional Info:

The 72530‑15P Cogent C30™ HPLC Column is designed for high‑resolution, shape‑selective separation of long‑chain hydrophobic compounds, delivering improved performance for positional and geometric isomers compared to conventional C18 phases.

This column utilizes a 30‑carbon bonded stationary phase on high‑purity silica (non‑end capped), providing stronger hydrophobic interaction and a distinct selectivity profile that enables separation of closely related structures under reversed‑phase conditions.

With a 200 Å pore size, it is particularly well suited for larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining consistent chromatographic performance and retention behavior.

✅ Comparable selectivity and application performance to YMC® C30 columns, making it a reliable alternative for USP L62 methods and equivalent analytical workflows

150 mm Length – High Resolution for Analytical Methods

The 150 mm length provides increased resolving power over shorter columns, enabling better separation of complex mixtures and difficult isomer systems.

  • Higher resolution than 50 mm and 100 mm columns

  • Improved separation of positional and geometric isomers

  • Increased peak capacity for complex analytical samples

✅ Use when greater separation is required for accurate identification and quantitation


Flow Rate & System Requirements (4.6 mm ID, 5 µm)

⚠️ Compatible with standard HPLC systems

  • Typical flow rate range: ~0.8–1.5 mL/min

  • Lower backpressure compared to 3 µm columns

  • Standard analytical detector compatibility

  • Stable flow delivery recommended for reproducibility

✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection

Why Choose C30 for Hydrophobic Separations

Shape Selectivity for Isomers

  • Resolves positional and geometric isomers

  • Provides separation beyond traditional C18 capability

Optimized for Larger Molecules

  • 200 Å pore supports complex analyte interaction

  • Ideal for carotenoids, vitamins, and peptides

Reversed‑Phase Alternative to Normal Phase

  • Avoids instability and reproducibility issues

  • Maintains consistent analytical performance

Cogent C30™ Advantages

Extended C30 Ligand

  • Stronger hydrophobic interaction than C18

  • Unique selectivity for long‑chain compounds

High Purity Silica

  • Consistent column‑to‑column performance

  • Reliable chromatographic reproducibility

Method Transfer Capability

  • Comparable to YMC® C30 column chemistry and applications

  • Suitable for transferring L62 methods with minimal modification

Typical Applications

  • Carotenoid and vitamin analysis

  • Isomer and positional compound separations

  • Peptide and large molecule separations

  • Hydrophobic compound profiling

  • Analytical method development and optimization

Important Usage Notes

  • Designed for standard analytical HPLC systems (4.6 mm ID)

  • Not end‑capped (intentional for enhanced selectivity)

  • Lower backpressure vs smaller particle sizes

  • Ideal for high‑resolution analytical workflows

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media