HPLC Column, C30, 5um, 4.6mm ID x 150mm Length, 200A. Cogent Brand. 1 EA.
Additional Info:
The 72530‑15P Cogent C30™ HPLC Column is designed for high‑resolution, shape‑selective separation of long‑chain hydrophobic compounds, delivering improved performance for positional and geometric isomers compared to conventional C18 phases.
This column utilizes a 30‑carbon bonded stationary phase on high‑purity silica (non‑end capped), providing stronger hydrophobic interaction and a distinct selectivity profile that enables separation of closely related structures under reversed‑phase conditions.
With a 200 Å pore size, it is particularly well suited for larger molecules, including carotenoids, vitamins, peptides, and some proteins, while maintaining consistent chromatographic performance and retention behavior.
✅ Comparable selectivity and application performance to YMC® C30 columns, making it a reliable alternative for USP L62 methods and equivalent analytical workflows
150 mm Length – High Resolution for Analytical Methods
The 150 mm length provides increased resolving power over shorter columns, enabling better separation of complex mixtures and difficult isomer systems.
Higher resolution than 50 mm and 100 mm columns
Improved separation of positional and geometric isomers
Increased peak capacity for complex analytical samples
✅ Use when greater separation is required for accurate identification and quantitation
Flow Rate & System Requirements (4.6 mm ID, 5 µm)
⚠️ Compatible with standard HPLC systems
Typical flow rate range: ~0.8–1.5 mL/min
Lower backpressure compared to 3 µm columns
Standard analytical detector compatibility
Stable flow delivery recommended for reproducibility
✅ Sample preparation requirement: filter samples using a 0.2 µm syringe filter prior to injection
Why Choose C30 for Hydrophobic Separations
Shape Selectivity for Isomers
Resolves positional and geometric isomers
Provides separation beyond traditional C18 capability
Optimized for Larger Molecules
200 Å pore supports complex analyte interaction
Ideal for carotenoids, vitamins, and peptides
Reversed‑Phase Alternative to Normal Phase
Avoids instability and reproducibility issues
Maintains consistent analytical performance
Cogent C30™ Advantages
Extended C30 Ligand
Stronger hydrophobic interaction than C18
Unique selectivity for long‑chain compounds
High Purity Silica
Consistent column‑to‑column performance
Reliable chromatographic reproducibility
Method Transfer Capability
Comparable to YMC® C30 column chemistry and applications
Suitable for transferring L62 methods with minimal modification
Typical Applications
Carotenoid and vitamin analysis
Isomer and positional compound separations
Peptide and large molecule separations
Hydrophobic compound profiling
Analytical method development and optimization
Important Usage Notes
Designed for standard analytical HPLC systems (4.6 mm ID)
Not end‑capped (intentional for enhanced selectivity)
Lower backpressure vs smaller particle sizes
Ideal for high‑resolution analytical workflows