Guard Column Cartridges, C30, 5um, 200A. 2.1mm ID x 10mm Length. Cogent Brand. 5/PK.

Additional Info:

The 72530‑PG1 Cogent C30™ Guard Column Cartridges are designed to protect 2.1 mm LC‑MS analytical columns from particulates, strongly retained compounds, and sample contamination, helping maintain consistent performance and extend column life.

Packed with 5 µm C30 stationary phase, these cartridges use a 30‑carbon bonded ligand on high‑purity silica (non‑end capped), ensuring matched selectivity with your analytical column while minimizing disruption to chromatographic behavior.

The 200 Å pore size provides compatibility with larger molecules, including carotenoids, vitamins, peptides, and similar compounds where shape selectivity is required.

✅ Comparable selectivity to YMC® C30 columns, ensuring seamless compatibility with equivalent LC‑MS methods and workflows

Guard Function – Protecting LC‑MS Performance

These guard cartridges act as a sacrificial protection layer, capturing contaminants before they reach both the analytical column and sensitive LC‑MS components.

  • Traps particulates and sample debris

  • Reduces adsorption of strongly retained compounds

  • Maintains retention time stability and peak shape

✅ Helps extend column lifetime and LC‑MS system reliability

Designed for 2.1 mm LC‑MS Columns

Optimized for:

  • 2.1 mm ID C30 analytical columns

  • Low‑flow LC‑MS and UHPLC systems

Maintains matching C30 chemistry and selectivity, ensuring consistent method performance.

Flow Rate & System Considerations (2.1 mm, 5 µm)

⚠️ Designed for low‑flow LC‑MS systems

  • Typical flow rate range: ~0.2–0.3 mL/min

  • Lower backpressure vs 3 µm guard cartridges

  • Minimal impact on system pressure and flow stability

  • Compatible with low‑volume LC‑MS detectors

✅ Install upstream of the analytical column for optimal protection

Why Use C30 Guard Cartridges

Maintain Shape Selectivity

  • Same C30 phase as analytical column

  • Preserves separation of positional and geometric isomers

Extend Column Lifetime

  • Prevents contamination reaching the main column

  • Reduces need for frequent replacement

Improve LC‑MS Reliability

  • Protects both column and detector

  • Maintains consistent analytical performance

Cogent C30™ Guard Advantages

Matched C30 Chemistry

  • Same selectivity as analytical column

  • Comparable to YMC® C30 column workflows

Durable 5 µm Media

  • Balanced efficiency and robustness

  • Lower pressure impact on LC‑MS systems

High‑Quality Construction

  • Stainless steel cartridge body

  • Stainless steel frits with PEEK caps

Typical Applications

  • LC‑MS carotenoid and vitamin analysis

  • Hydrophobic and isomer separations

  • Peptide and large molecule workflows

  • Analytical method protection

  • Routine LC‑MS analysis