Guard Column Starter Set, Amide, complete with 5 each 4.0 mm ID x 10 mm long cartridges packed with 4 um, 100 A phase and 1 each guard column holder. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40036‑PG4 Amide Guard Column Starter Set provides everything required to implement Cogent TYPE‑C™ guard column protection for larger‑ID Amide HILIC analytical columns. This complete starter kit is designed to protect analytical columns from particulates, strongly retained contaminants, and irreversible matrix components that can degrade chromatographic performance and shorten column life.

The kit includes a stainless‑steel guard cartridge column holder compatible with TYPE‑C™ guard cartridges, along with five Amide guard cartridges packed with 4 µm, 100 Å Amide stationary phase.

Guard Column Use Case: Amide HILIC Protection for Larger‑ID Analytical Columns

Guard columns act as a sacrificial protection stage installed upstream of the analytical column. When running HILIC methods using Amide chemistry on 3.0–4.6 mm ID analytical columns, guard columns help:

  • Protect analytical columns from particulate contamination

  • Trap strongly retained or irreversible sample components

  • Preserve chromatographic selectivity, peak shape, and retention stability

  • Extend analytical column lifetime and reduce replacement frequency

Guard protection is strongly recommended for polar, matrix‑rich samples, including food, biological, metabolomics, and pharmaceutical HILIC workflows.

What’s Included in the Starter Set

This guard column starter kit includes:

Based on average analytical use, the five included cartridges typically provide sufficient protection for the lifetime of one analytical column.

Each guard cartridge is shipped in an individual, closeable Delrin® storage case to prevent drying, contamination, or handling damage prior to installation.

Phase Consistency: Amide TYPE‑C™ Chemistry

The guard cartridges in this kit are packed with the same Amide TYPE‑C™ silica hydride chemistry used in corresponding analytical columns, ensuring:

  • No change in chromatographic selectivity or elution order

  • Minimal added dead volume

  • Seamless integration into existing Amide HILIC methods

  • Stable performance under high‑organic HILIC conditions

Maintaining phase consistency is essential to preserving method integrity when guard protection is implemented.

Compatibility & Recommended Use

  • Designed for 3.0 mm, 4.0 mm, and 4.6 mm ID analytical HPLC columns

  • Compatible with Cogent TYPE‑C™ Amide analytical columns

  • Suitable for HILIC workflows targeting sugars, amines, and highly polar analytes

This starter set is ideal for laboratories implementing guard protection on larger‑diameter analytical columns or standardizing Amide guard usage across multiple methods.

Operational Notes

  • Guard cartridges can be replaced quickly without removing the analytical column

  • Replacement frequency depends on sample cleanliness and matrix complexity

  • Guard use is strongly recommended for LC‑MS, food, metabolomics, biological, and other complex polar samples

 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media