Guard Column Starter Set, Silica-C, complete with 5 each 4.0 mm ID x 10 mm long cartridges packed with 4 um, 100 A phase and 1 each guard column holder. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40000‑PG4 Silica‑C™ Guard Column Starter Set provides everything needed to implement Cogent TYPE‑C™ guard column protection for larger‑ID analytical HPLC methods using Silica‑C™ chemistry. This complete starter kit is designed to protect analytical columns from particulates, strongly retained contaminants, and matrix components that can degrade performance and shorten column life.

The kit includes a stainless‑steel guard cartridge column holder compatible with all TYPE‑C™ guard cartridges, along with five Silica‑C™ guard cartridges packed with 4 µm, 100 Å Silica‑C™ stationary phase.

Guard Column Use Case: Silica‑C™ Protection for Larger‑ID Analytical Methods

Guard columns act as a sacrificial protection stage installed upstream of the analytical column. When running HILIC or normal‑phase methods with Silica‑C™ chemistry on 3.0–4.6 mm ID columns, guard columns help:

  • Protect analytical columns from particulate contamination

  • Trap strongly retained or irreversible sample components

  • Preserve chromatographic selectivity, peak shape, and retention stability

  • Extend analytical column lifetime and reduce replacement costs

Routine guard use helps maintain consistent performance in demanding analytical workflows.

What’s Included in the Starter Set

This guard column starter kit includes:

Based on average analytical use, the five included cartridges typically provide sufficient protection for the lifetime of one analytical column.

Each guard cartridge is shipped in an individual, closeable Delrin® storage case to prevent drying, contamination, or handling damage prior to installation.

Phase Consistency: Silica‑C™ TYPE‑C™ Chemistry

The guard cartridges in this kit are packed with the same Silica‑C™ TYPE‑C™ silica hydride chemistry used in corresponding analytical columns, ensuring:

  • No change in chromatographic selectivity or elution order

  • Minimal added dead volume

  • Seamless integration into existing Silica‑C™ methods

  • Stable performance under HILIC and normal‑phase conditions

Phase consistency is essential to preserve method integrity when using guard protection.

Compatibility & Recommended Use

  • Designed for 3.0 mm, 4.0 mm, and 4.6 mm ID analytical HPLC columns

  • Compatible with Cogent TYPE‑C™ analytical columns

  • Suitable for HILIC and normal‑phase workflows using Silica‑C™ chemistry

This starter set is ideal for laboratories implementing guard protection on larger‑diameter analytical columns or standardizing guard usage across multiple methods.

Operational Notes

  • Guard cartridges are easily replaced without removing the analytical column

  • Replacement frequency depends on sample cleanliness and matrix complexity

  • Guard use is strongly recommended for LC‑MS, biological, and complex sample matrices

 