Guard Column Starter Set, UDA (wcx), complete with 5 each 2.0 mm ID x 10 mm long cartridges packed with 4 um, 100 A phase and 1 each guard column holder. Cogent TYPE-C Brand. 1 EA.
Additional Info:
40031-PG1 Cogent UDA™ (WCX) Guard Column Starter Set provides everything needed to begin protecting analytical columns while maintaining the unique mixed‑mode selectivity of the UDA™ stationary phase.
This kit includes a stainless steel guard column holder and five guard column cartridges, each packed with 4 µm, 100 Å Cogent UDA™ (WCX) TYPE‑C silica. These cartridges utilize the same Undecanoic Acid ligand chemistry as the analytical columns, ensuring consistent chromatographic behavior.
The UDA™ stationary phase features an 11‑carbon hydrophobic chain with a terminal carboxylic acid group, enabling:
Reversed phase (hydrophobic interactions)
Weak cation exchange (active at pH ≥ 6)
HILIC (polar interaction capability)
This matched chemistry ensures that while contaminants are trapped, method selectivity and retention remain consistent.
Each cartridge is packaged individually in protective, resealable Delrin cases, preventing drying or damage prior to use.
2.1 mm ID System Compatibility – Low‑Flow Protection
Designed specifically for narrow‑bore analytical columns.
Optimized for 2.1 mm ID analytical columns
Maintains low dispersion for LC‑MS and UHPLC workflows
Protects against particulates and strongly retained contaminants
Preserves column performance and efficiency
✅ Recommended for all UDA™ analytical workflows using 2.1 mm ID columns
Flow Rate & System Requirements (2.1 mm ID, 4 µm)
⚠️ Requires low‑flow capable HPLC or UHPLC system
Typical flow rate range: ~0.2 – 0.4 mL/min
Moderate backpressure (4 µm particles)
Designed for low‑dispersion systems
Compatible with UV and MS detection
✅ Important: Systems must provide stable low‑flow performance for 2.1 mm ID columns
✅ Best Practice: Replace cartridges regularly to maintain protection and chromatographic integrity
Why Use UDA™ Guard Columns
Protects Analytical Columns
Prevents contamination from particulates and matrix components
Reduces irreversible adsorption of strongly retained compounds
Maintains Method Selectivity
Matches UDA™ mixed‑mode chemistry (RP, WCX, HILIC)
Ensures consistent retention and reproducibility
Extends Column Lifetime
Reduces column replacement frequency
Improves method robustness
TYPE‑C Silica Advantages
Faster Equilibration
Reduces downtime between runs
No Strict Moisture Control (HILIC)
Simplifies mobile phase preparation
Extreme Robustness
Stable at low pH (<2)
Resistant to hydrolysis
Long Cartridge Life
Durable under routine analytical use
Cogent UDA™ Guard Kit Advantages
Complete Starter Solution
Includes holder and cartridges
Matched Chemistry
Ensures seamless method compatibility
Convenient Packaging
Individual cartridge storage cases preserve performance
Optimized for LC‑MS Workflows
Low dispersion and MS compatibility
Typical Applications
LC‑MS analytical workflows
Complex matrix separations
Method development and routine testing
Basic and ionizable compound analysis
Pharmaceutical and bioanalytical workflows
Important Usage Notes
Designed for 2.1 mm ID analytical columns only
Replace cartridge when backpressure increases or performance decreases
Ensure holder is properly installed for optimal performance
Store unused cartridges in protective cases