Guard Column Starter Set, Phenyl Hydride 2.o, complete with 5 each 2.0 mm ID x 10 mm long cartridges packed with 2.2 um, 120 A phase and 1 each guard column holder. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 69220‑PG1 Phenyl Hydride 2.o Guard Column Starter Set provides everything required to implement Cogent TYPE‑C™ guard column protection for high‑efficiency Phenyl Hydride 2.o analytical methods. This complete starter kit is designed to protect analytical columns from particulates, strongly retained contaminants, and irreversible matrix buildup, helping maintain chromatographic performance and extend column lifetime in high‑pressure workflows.

This starter set includes a stainless‑steel guard cartridge column holder suitable for high‑pressure operation and five Phenyl Hydride 2.o guard cartridges packed with 2.2 µm, 120 Å Phenyl Hydride 2.o stationary phase.

Guard Column Use Case: Phenyl Hydride 2.o Protection for High‑Pressure Methods

Guard columns act as a sacrificial protection stage installed upstream of the analytical column. When using Phenyl Hydride 2.o chemistry, particularly in HILIC‑mode and high‑pressure analytical workflows, guard columns help:

  • Protect analytical columns from particulate contamination

  • Trap strongly retained or irreversible sample components

  • Preserve selectivity, peak shape, and retention reproducibility

  • Extend the usable lifetime of high‑efficiency analytical columns

The Phenyl Hydride 2.o guard format is especially valuable for small‑particle methods, where contamination can quickly impact performance.

What’s Included in the Starter Set

This guard column starter kit includes:

Based on average analytical use, the five included cartridges typically provide sufficient protection for the lifetime of one analytical column.

Each guard cartridge is shipped in an individual, closeable Delrin® storage case to prevent drying, contamination, or handling damage prior to installation.

Phenyl Hydride 2.o Stationary Phase Consistency

The guard cartridges in this kit are packed with the same Phenyl Hydride 2.o chemistry used in corresponding analytical columns, ensuring:

  • No change in chromatographic selectivity or elution order

  • Minimal added dead volume

  • Seamless integration into existing Phenyl Hydride 2.o HILIC methods

  • Stable performance under high‑organic mobile‑phase conditions

Phase consistency is critical for maintaining method integrity when guard protection is implemented.

Compatibility & Recommended Use

  • Designed for 2.1 mm ID analytical Phenyl Hydride 2.o columns

  • Compatible with Cogent TYPE‑C™ analytical columns

  • Suitable for HILIC‑mode analytical HPLC workflows

  • Requires the included Cogent TYPE‑C™ guard column holder

Operational Notes

  • Guard cartridges are easily replaced without removing the analytical column

  • Replacement frequency depends on sample cleanliness and matrix complexity

  • Guard use is strongly recommended for LC‑MS, biological, and complex sample applications, especially with 2.2 µm particle columns

 