HPLC Column, Silica-C, 4um, 2.1mm ID x 150mm Length, 100A. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40000‑15P‑2 Silica‑C™ HPLC Column is manufactured using Cogent TYPE‑C™ silica hydride technology, providing distinct selectivity, rapid equilibration, and robust performance for HILIC and normal‑phase separations. Unlike conventional bonded‑silica phases, this unmodified silica hydride surface contains no end‑capping or organic ligands, delivering stable retention and improved method reproducibility—especially advantageous in moisture‑sensitive normal‑phase workflows.

This column is optimized for analytes requiring non‑aqueous or minimally aqueous mobile phases, where traditional silica columns may present variability due to water adsorption.

Application Focus: Silica‑C™ for HILIC & Normal‑Phase Separations

Silica‑C™ stationary phases are selected for the analysis of compounds that are not soluble in water or require non‑polar solvent systems. The Silica‑C™ phase is particularly effective for:

  • Lipids

  • Peptides and proteins

  • Oligonucleotides

  • Other analytes requiring non‑polar solvents or HILIC conditions

The silica hydride surface supports reproducible retention and improved method stability compared to conventional silica phases.

Key Advantages of Silica‑C™ TYPE‑C™ Technology

Compared to traditional bonded‑silica columns, Silica‑C™ columns provide:

  • Faster equilibration between injections

  • No need to control moisture in mobile‑phase solvents

  • Robust column lifetime under demanding solvent conditions

  • Distinct selectivity, particularly beneficial in normal‑phase separations

These attributes make Silica‑C™ a dependable solution for consistent, non‑aqueous analytical workflows.

Why Choose the 2.1 mm × 150 mm Format

The 2.1 mm ID × 150 mm length configuration is commonly selected when expanded resolution and sensitivity are required, particularly for LC‑MS applications:

  • Higher resolving power than 50 mm and 100 mm formats

  • Increased peak capacity for complex mixtures

  • Reduced solvent consumption compared to larger‑diameter columns

  • Excellent LC‑MS compatibility, with lower solvent flow to the MS source

This narrow‑bore, long‑column format is ideal when separation confidence takes priority over the shortest run time.

Particle Size and Performance

The 4 µm particle size provides reliable efficiency with manageable backpressure, delivering consistent peak shape and reproducibility on standard analytical HPLC systems while enabling high‑resolution separations of closely eluting analytes.

System Requirements and Flow Rates

  • Typical flow range (2.1 mm ID): ~0.2–0.3 mL/min

  • System capability: Requires an HPLC system capable of accurate, stable low‑flow delivery

  • Important note: Not all standard HPLC systems are suitable for reliable operation at these reduced flow rates

Flow‑rate optimization should consider mobile‑phase viscosity, column temperature, and system pressure limits.

 