This items is made to order and is not returnable and order cannot be canceled.

CUSTOM ITEM: HPLC Column, Bidentate C18, 4um, 4.6mm ID x 75mm Length, 100A. Cogent TYPE-C Brand. 1 EA.

Additional Info:

The 40018‑75P Cogent Bidentate C18™ HPLC Column is a custom‑manufactured analytical column designed for applications requiring additional retention and resolving power beyond standard short‑length formats. Constructed using Cogent TYPE‑C™ silica hydride technology, this column delivers unique selectivity, fast equilibration, and exceptional chemical robustness not achievable with conventional silica‑based C18 phases.

The stationary phase consists of an aliphatic C18 chain bonded via two direct silicon–carbon bonds (bidentate attachment) to a silica hydride surface. This design yields a stationary phase that is highly hydrophobic yet unusually versatile, capable of retaining compounds that often show poor retention on traditional C18 columns. The column can be operated with 100 % aqueous mobile phases without phase collapse and can tolerate very low pH conditions (below pH 2) without degradation.

The 75 mm column length provides increased interaction time compared to 50 mm formats, improving separation of closely eluting compounds while maintaining reasonable run times. This makes the column well suited for challenging analytical separations where extended resolution is required.

Why Choose the 75 mm Bidentate C18™ Format

Compared to shorter analytical columns, the 75 mm length offers:

  • Improved resolution for closely related analytes

  • Greater method flexibility for gradient optimization

  • Enhanced selectivity when additional retention is required

Coupled with TYPE‑C™ silica hydride chemistry, this format maintains fast equilibration and long column lifetime even under aggressive method conditions.

Key Features

Cogent TYPE‑C™ Silica Hydride Technology

  • Non‑traditional reversed‑phase chemistry

  • Reduced silanol activity and secondary interactions

  • Faster equilibration than conventional C18 columns

  • Extremely robust column lifetime

Bidentate C18™ Bonding

  • Two‑point attachment via direct Si–C bonds

  • Unique selectivity compared to standard C18 phases

  • Retains hydrophobic compounds and select hydrophilic analytes

Exceptional Method Flexibility

  • Compatible with 100 % aqueous mobile phases

  • Stable at very low pH (below 2)

  • Suitable for unconventional or aggressive methods

Analytical‑Scale Performance

  • 4.6 mm ID × 75 mm length

  • Increased resolving power vs. shorter columns

  • Compatible with standard analytical HPLC systems

Typical Applications

  • Challenging reversed‑phase separations

  • Compounds poorly retained on conventional C18 columns

  • Low‑pH analytical methods

  • Aqueous‑dominant mobile phases

  • Method development and optimization

Made‑to‑Order & Pricing Information

This is a custom, made‑to‑order item.

  • Orders cannot be canceled once placed

  • Custom items are non‑returnable

Custom Order Item. Inquire for more information.