HPLC Column, UDA (wcx), 4um, 4.6mm ID x 100mm Length, 100A. Cogent TYPE-C Brand. 1 EA..
Additional Info:
40031-10P Cogent UDA™ (weak cation exchange, WCX) HPLC Column is built on Cogent TYPE‑C™ silica (silica hydride platform), offering a unique mixed‑mode retention mechanism that combines reversed phase, ion exchange, and HILIC interactions in a single column.
The UDA™ ligand (Undecanoic Acid) features an 11‑carbon hydrophobic chain with a terminal carboxylic acid functional group, enabling:
Reversed phase (hydrophobic retention)
Weak cation exchange (active at pH ≥ 6)
HILIC (polar interaction capability)
This combination provides enhanced selectivity for basic, polar, and ionizable compounds, making it especially valuable for complex matrices where traditional C18 or ion exchange phases are limited.
The TYPE‑C silica hydride base delivers significant performance advantages:
Direct silicon–carbon bonding for superior chemical stability
Operates at very low pH (<2) without damage
Faster equilibration compared to traditional silica columns
Reduced sensitivity to mobile phase moisture in HILIC mode
100 mm Length – Balanced Resolution for Routine HPLC
The 100 mm length provides an optimal balance between separation efficiency and analysis time in conventional HPLC workflows.
Greater resolution than 50 mm columns
Faster run times than longer formats
Improved separation of closely related compounds
✅ Recommended for routine HPLC methods when 50 mm columns lack sufficient resolution
Flow Rate & System Requirements (4.6 mm ID, 4 µm)
✅ Fully compatible with standard HPLC systems
Typical flow rate range: ~1.0 – 1.5 mL/min
Moderate backpressure
Compatible with UV and MS detectors
Suitable for conventional analytical systems
✅ Best Practice: Use sample filtration and a guard column to extend column life and maintain performance
Unique Selectivity – Why Choose UDA™ (WCX)
True Mixed‑Mode Retention
Hydrophobic (RP)
Ionic (weak cation exchange)
Polar (HILIC)
Ideal for Complex Matrices
Resolves co‑eluting compounds
Effective for basic and positively charged analytes
pH‑Controlled Selectivity
WCX mechanism active at pH ≥ 6
Retention can be tuned using pH and ionic strength
✅ Ideal when C18 or traditional ion exchange methods do not achieve desired separation
TYPE‑C Silica Advantages
Extreme Robustness
Stable under aggressive conditions including low pH
Resistant to hydrolysis
Faster Equilibration
Reduces cycle time between runs
No Strict Moisture Control (HILIC Mode)
Simplifies method development
Long Column Lifetimes
Durable chemistry for routine use
Cogent UDA™ Column Advantages
Multi‑Mode Flexibility
RP, HILIC, and WCX in one column
Standard HPLC Compatibility (4 µm)
No need for UHPLC system
Lower pressure than sub‑2 µm columns
Balanced Performance
Strong efficiency with manageable backpressure
Typical Applications
Routine analytical HPLC methods
Complex matrix separations
Basic and positively charged compounds
Polar and ionizable analytes
Pharmaceutical and bioanalytical workflows
Important Usage Notes
Packed and shipped in reversed‑phase solvents
Compatible with standard HPLC systems
Suitable for hydrophilic and hydrophobic compounds
pH control is critical for WCX selectivity